VENSİS • VORTICE FAN TÜRKİYE0312 945 13 61  •  satis@vensis.com.tr
HomeProductsCataloguesKnowledge CenterReferencesContactGET A QUOTE
Products / VORTICENT CRC-R
Corrosion-resistant Centrifugal Fans
Vortice product family

VORTICENT CRC-R

VORTICENT CRC-R is a medium-pressure centrifugal fan for corrosive air and chemical fumes, using a PE casing and PP backward-curved impeller.

VORTICENT CRC-R Vortice
Official Vortice product image

Product overview

VORTICENT CRC-R is a medium-pressure centrifugal fan for corrosive air and chemical fumes, using a PE casing and PP backward-curved impeller.

Key features

  • PE plastic fan casing
  • PP backward-curved self-cleaning impeller
  • IP55 Class F motor
  • 230/400 V 50 Hz
  • Chemical, petrochemical and laboratory duties
  • Up to 70°C for clean air

Application & selection

For laboratory, chemical-process and gas-cabinet exhaust where resistance to corrosive gases/vapours is more important than with standard metal fans.

Position in the range

CRC-A uses a forward-curved PP impeller, while CRC-R uses a backward-curved design with a different pressure/efficiency characteristic.

Models and variants

16 verified model/variant

Technical data verified from official Vortice product pages and Fan Selection Pro
Code: 30118

VORTICENT CRC-R 20/2 T

Voltage230/400 V
IPIP55
Size20
Poles2 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30119

VORTICENT CRC-R 20/4 T

Voltage230/400 V
IPIP55
Size20
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30120

VORTICENT CRC-R 25/2 T

Voltage230/400 V
IPIP55
Size25
Poles2 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30121

VORTICENT CRC-R 25/4 T

Voltage230/400 V
IPIP55
Size25
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30122

VORTICENT CRC-R 28/2 T

Voltage230/400 V
IPIP55
Size28
Poles2 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30123

VORTICENT CRC-R 28/4 T

Voltage230/400 V
IPIP55
Size28
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30124

VORTICENT CRC-R 31/2 T

Voltage230/400 V
IPIP55
Size31
Poles2 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30125

VORTICENT CRC-R 31/4 T

Voltage230/400 V
IPIP55
Size31
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30126

VORTICENT CRC-R 31/6 T

Voltage230/400 V
IPIP55
Size31
Poles6 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30127

VORTICENT CRC-R 35/2 T

Voltage230/400 V
IPIP55
Size35
Poles2 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30128

VORTICENT CRC-R 35/4 T

Voltage230/400 V
IPIP55
Size35
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30129

VORTICENT CRC-R 35/6 T

Voltage230/400 V
IPIP55
Size35
Poles6 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30130

VORTICENT CRC-R 40/4 T

Voltage230/400 V
IPIP55
Size40
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30131

VORTICENT CRC-R 40/6 T

Voltage230/400 V
IPIP55
Size40
Poles6 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30132

VORTICENT CRC-R 45/4 T

Voltage230/400 V
IPIP55
Size45
Poles4 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Code: 30133

VORTICENT CRC-R 45/6 T

Voltage230/400 V
IPIP55
Size45
Poles6 pole
ImpellerPP backward-curved
CasingPE
Max Clean-air Temp70°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Let us evaluate this series for your project.

Contact Vensis for model selection, technical suitability and quotation.

Request Quote