VENSİS • VORTICE FAN TÜRKİYE0312 945 13 61  •  satis@vensis.com.tr
HomeProductsCataloguesKnowledge CenterReferencesContactGET A QUOTE
Products / VORTICENT CMS-KTM
Cubic Medium-pressure Fans
Vortice product family

VORTICENT CMS-KTM

VORTICENT CMS-KTM combines a backward-curved impeller with a robust cubic casing and B5 motor arrangement in a direct-drive medium-pressure centrifugal fan.

VORTICENT CMS-KTM Vortice
Official Vortice product image

Product overview

VORTICENT CMS-KTM combines a backward-curved impeller with a robust cubic casing and B5 motor arrangement in a direct-drive medium-pressure centrifugal fan.

Key features

  • Compact C3-painted cubic casing
  • Backward-curved self-cleaning impeller
  • Direct B5 motor drive
  • IP55 Class F motor
  • Conveyed air up to 130°C
  • Ambient temperature up to 60°C

Application & selection

For medium-pressure duct/process duties requiring robust service access and elevated conveyed-air temperature capability.

Position in the range

Compared with CMS-NMU, its cubic rigid casing and 130°C conveyed-air capability give it a heavier-duty character.

Models and variants

23 verified model/variant

Technical data verified from official Vortice product pages and Fan Selection Pro

VORTICENT CMS KTM 354 T2 3kW

Power3 kW
Voltage230/400 V
IPIP55
Size354
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 401 T2 4kW

Power4 kW
Voltage230/400 V
IPIP55
Size401
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 564 T4 3kW

Power3 kW
Voltage230/400 V
IPIP55
Size564
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 631 T4 4kW

Power4 kW
Voltage230/400 V
IPIP55
Size631
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 714 T4 11kW

Power11 kW
Voltage400/690 V
IPIP55
Size714
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 801 T4 15kW

Power15 kW
Voltage400/690 V
IPIP55
Size801
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 311 T2 1,1kW

Power1,1 kW
Voltage230/400 V
IPIP55
Size311
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 314 T2 1,5kW

Power1,5 kW
Voltage230/400 V
IPIP55
Size314
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 351 T2 2,2kW

Power2,2 kW
Voltage230/400 V
IPIP55
Size351
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 404 T2 5,5kW

Power5,5 kW
Voltage400/690 V
IPIP55
Size404
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 454 T4 1,1kW

Power1,1 kW
Voltage230/400 V
IPIP55
Size454
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 501 T4 1,5kW

Power1,5 kW
Voltage230/400 V
IPIP55
Size501
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 504 T4 2,2kW

Power2,2 kW
Voltage230/400 V
IPIP55
Size504
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 561 T4 2,2kW

Power2,2 kW
Voltage230/400 V
IPIP55
Size561
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 634 T4 5,5kW

Power5,5 kW
Voltage400/690 V
IPIP55
Size634
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 711 T4 7,5kW

Power7,5 kW
Voltage400/690 V
IPIP55
Size711
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 311 T4 0,37kW

Power0,37 kW
Voltage230/400 V
IPIP55
Size311
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 314 T4 0,37kW

Power0,37 kW
Voltage230/400 V
IPIP55
Size314
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 351 T4 0,37kW

Power0,37 kW
Voltage230/400 V
IPIP55
Size351
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 354 T4 0,37kW

Power0,37 kW
Voltage230/400 V
IPIP55
Size354
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 401 T4 0,55kW

Power0,55 kW
Voltage230/400 V
IPIP55
Size401
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 404 T4 0,55kW

Power0,55 kW
Voltage230/400 V
IPIP55
Size404
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

VORTICENT CMS KTM 451 T4 0,75kW

Power0,75 kW
Voltage230/400 V
IPIP55
Size451
DriveDirect / B5
Max Air Temp130°C

Model fields are populated only where published by official Vortice sources; unpublished performance values are not inferred.

Let us evaluate this series for your project.

Contact Vensis for model selection, technical suitability and quotation.

Request Quote